Selfs - Current--compensated Noise Suppression Chokes - FAMILLE 42E16 H2 42E16 V2
LINEAR VERSION | Voltage 250 Vac Current 0.25 to 0.6 A |
These chokes are fitted with two high-permeability E16 cores (ferrite). They are mainly used in devices
equipped with switched-mode power supplies, and in filters designed to prevent both the spread of
parasitic noise within the device, and the effects of line noise on the device itself.
Types | Horizontal mounting | Vertical mounting | Rated curent A | Rated inductance mH | DC resistance per (typical) Ω |
42E16 H2 42E16 V2 | 42E16H2 0201 | 42E16V2 0201 | 0,25 | 39 | 2,5 |
42E16H2 0301 | 42E16V2 0301 | 0,35 | 27 | 1,5 | |
42E16H2 0400 | 42E16V2 0400 | 0,4 | 18 | 1,1 | |
42E16H2 0600 | 42E16V2 0600 | 0,6 | 10 | 0,7 |
Rated current: referred to 250 V-50 Hz and +60°C ambient temperature
Rated inductance: at +20°C and 1 kHz, 1 Vac
Inductance tolerance: +50 -30%
Inductance loss: < 10% at DC initial loading with IR
Testing voltage: 1500 V -50 Hz, 2 sec, winding to winding
Climatic category: DIN GKC (-40 to +125°C; humidity cat. C)
DC resistance: at +20°C
Derating operating current: at +120°C ambient temperature I=0
Overtemperature of windings: < 55°C
Max. permissible temperature of windings: 115 °C
Approx. weight: 13 g
Pending Approval: VDE
The chokes are designed and tested in accordance with EN 138100; EN 60938
The coil formers are of flame-retardant plastic material in accordance with UL 94V-0