Transformateurs / transformers - Power Line Modem Transformers - FAMILLE 63V19 21 0 63V19 21 3
These transformers are suitable to interface the power line modem. They find a wide application
wherever an high isolation resonant coupling is required.
TYPES
Types | Code | Turns ratio PRI/SEC ± 2% | Turns ratio tap (1-3/2-3) ± 2% | PRI inductance | PRI Leak inductance typical µh | Capacity PRI/SEC pF | Unloaded tactor Ω typical | Test voltage (2 sec) KV |
63V19 21 0 63V19 21 3 | 63V19 2100 | 2 : 1 | ≥2 mH | 3 | 15 | 4 | ||
63V19 2101 | 1 : 1 | ≥1- mH | 3 | 15 | 4 | |||
63V19 2130 | 5 : 1 | 5 : 1 | 207 µH | 15 | 30 | 4 | ||
63V19 2131 | 3.28 : 1 | 3.28 : 1 | 265 µH | 15 | 35 | 4 |
Technical Data
Primary inductance: at 20°C and 10 kHz, 0.1 mA
Primary Inductance tolerance: ±15% for 63V19 21 30 and 63V19 21 31 types (MPP core)
Primary leakage inductance: at 20°C and 100 kHz
Unloaded Q factor: at 20°C and 100 kHz
Approx. weight: 5 g
The transformers are designed and tested in accordance with EN 138100; EN 60938
The cases are of flame-retardant plastic material in accordance with UL 94V-0