Transformateurs / transformers - Current Sense Transformers - FAMILLE 69V25
These current sense transformers are fitted with high-permeability toroidal core (ferrite) and feature
across the secondary (under given conditions) a voltage proportional to the primary current.
They are used as control and protection devices to sense current without any disturbance to the
circuits in SMPS, lighting and UPS equipment.
![]() |

Types | Code | Code | Turns ratio Pri/Sec | PRI current A | SEC induct mH Rated | DC resistance Ω max. | Recomm. Terminat. Resist. Ω nom. | Schem |
69V25 | 69V25 5050 | 69V25T 5050 | 1/50 | 5 | 5 | 0.7 | 50 | A |
69V25 5100 | 69V25T 5100 | 1/100 | 5 | 20 | 1.4 | 100 | A | |
69V25 5200 | 69V25T 5200 | 1/200 | 5 | 80 | 4.5 | 200 | A | |
69V25 5300 | 69V25T 5300 | 1/300 | 5 | 180 | 11 | 300 | A | |
69V25 A050 | 69V25T A050 | 1/50 | 10 | 5 | 0.7 | 50 | B | |
69V25 A100 | 69V25T A100 | 1/100 | 10 | 20 | 1.4 | 100 | B | |
69V25 A200 | 69V25T A200 | 1/200 | 10 | 80 | 4.5 | 200 | B | |
69V25 A300 | 69V25T A300 | 1/300 | 10 | 180 | 11 | 300 | B |

Rated inductance: at +20°C and 10 kHz, 0.1 mA
Inductance tolerance: +50 -30%
Operating frequency: 20 kHz plus
Current primary peak (1 turn): 20A
Operating temperature: -30 to +125°C
Dielectric strenght Pri/Sec: 4000 Vac
Scale factor with rated terminating resistance: Vout 1V per 1A
Approx. weight: 12 g
See technical notes p. 92.