Transformateurs / transformers - Current Sense Transformers - FAMILLE 67U13V2





These current sense transformers are fitted with high-permeability core (ferrite) U13 size and feature
across the secondary (under given conditions) a voltage proportional to the primary current.
They are used as control and protection devices to sense current without any disturbance to the
circuits in SMPS, lighting and UPS equipment.

TYPES

Types Code Turns ratio Pri/Sec PRI current A SEC induct mH (Rated) DC resistance Ω max.
67U13V2 67U13V2 00501/50253.52
67U13V2 01001/10025154.5
67U13V2 02001/20025609
67U13V2 03001/3002512014
67U13V2 05001/5002535025
67U13V2 07001/7002564040

Technical Data

Rated inductance: at +20°C and 10 kHz, 0.1 mA
Inductance tolerance: +50 -30%
Operating frequency: 20 kHz plus
Current primary peak (1 turn): 20A
Operating temperature: -30 to +125°C
Dielectric strenght Pri/Sec: 1500 Vac
Scale factor with rated terminating resistance: Vout 1V per 1A
Approx. weight: 8 gThe transformers are designed and tested in accordance with EN 138100; EN 60938-1
The coil formers are of flame-retardant plastic material in accordance with UL 94V-0