These transformers are fitted with high-permeability toroid core (ferrite). They have small dimensions
and good coupling. They are mainly used in electronic transformers for halogen lamps and in switched
-mode power supplies.

TYPES
Types |
Code |
Rated power W |
Supply voltage V |
PRI voltage V |
SEC voltage V |
PRI inductance mH |
65A19 |
65A19 0600 | 60 | 230 | 130 - 170 | 12 | 20
|
65A19 0601 | 60 | 230 | 130 - 170 | 13 | 20
|
65A19 0602 | 60 | 115 | 65 - 85 | 12 | 5
|

Technical Data
The table shows the basic versions. Customized types can be supplied according to customer's
specifications.
Test voltage prim. /sec.: 3750 V/50 Hz - 1 min
Primary inductance.: measured at 10 kHz
Approx. weight: 22 g
Approval: EN 61046 Annex C - EN 60065 - 14.3.2 a
The cases are of flame-retardant plastic material in accordance with UL 94V-0