Power 200 W at 30 kHz 250 W at 30 kHz
|
These transformers are fitted with high-permeability toroid core (ferrite). They have small dimensions
and good coupling. The are mainly used in electronic transformers for halogen lamps and in switchedmode
power supplies.

TYPES
Types |
Code |
Rated power W |
Supply voltage V |
PRI voltage V |
SEC voltage V |
PRI inductance mH |
Mounting holes |
Approx. Weight g |
Prim. Pins Ø |
Sec. Pins Ø |
65D33 |
65D33 2000 | 200 | 230 | 130 - 170 | 12 | 16 | 1,3 | 1,7 | 80
|
65D33 2001 | 200 | 115 | 65 - 85 | 12 | 3 | 1,3 | 1,3 | 80
|
65D33 2500 | 250 | 230 | 130 - 170 | 12 | 15 | 1,3 | 1,8 | 85
|

Technical Data
The table shows the basic versions. Customized types can be supplied according to customer's
specifications.
Test voltage prim. /sec.: 3750 V/50 Hz - 1 min
Primary inductance.: measured at 10 kHz
Approval: EN 61046 Annex C - EN 60065 - 14.3.2 a
The cases are of flame-retardant plastic material in accordance with UL 94V-0