Welcome

Transformateurs / transformers - Power Line Modem Transformers - FAMILLE 63V19 21 0 63V19 21 3





These transformers are suitable to interface the power line modem. They find a wide application
wherever an high isolation resonant coupling is required.

TYPES

Types Code Turns ratio PRI/SEC ± 2% Turns ratio tap (1-3/2-3) ± 2% PRI inductance PRI Leak inductance typical µh Capacity PRI/SEC pF Unloaded tactor Ω typical Test voltage (2 sec) KV
63V19 21 0 63V19 21 3 63V19 21002 : 1≥2 mH3154
63V19 21011 : 1≥1- mH3154
63V19 2130 5 : 15 : 1207 µH15304
63V19 21313.28 : 13.28 : 1265 µH15354

Technical Data

Primary inductance: at 20°C and 10 kHz, 0.1 mA
Primary Inductance tolerance: ±15% for 63V19 21 30 and 63V19 21 31 types (MPP core)
Primary leakage inductance: at 20°C and 100 kHz
Unloaded Q factor: at 20°C and 100 kHz
Approx. weight: 5 g

The transformers are designed and tested in accordance with EN 138100; EN 60938
The cases are of flame-retardant plastic material in accordance with UL 94V-0